Generation that keeps performing after the installers leave.
Introduction
What this covers
Solar plants are usually installed well and maintained poorly. Output falls quietly through soiling, string faults, failed optimisers, degraded connectors and inverters nobody has checked since commissioning.
IIM works on solar generation as electrical infrastructure rather than as a consumer product — with the testing equipment and the electrical discipline that industrial and commercial installations require.
Scope of services
What we take on within this discipline.
01
PV array maintenance
Module inspection, cleaning regimes, mounting and connector attention across rooftop and ground-mounted arrays.
02
String & array testing
String voltage and current measurement, insulation testing and identification of underperforming strings.
03
Inverter services
Inspection, cleaning, fault diagnosis and maintenance of string and central inverters.
04
Performance assessment
Comparison of actual generation against expectation, with findings and remedial recommendations.
05
Protection & earthing
DC and AC protection checks, surge-protection condition and earthing verification.
06
System expansion support
Technical support for extending or re-configuring existing installations.
Equipment & systems covered
Photovoltaic modules and arrays
String and central inverters
DC combiner boxes and string protection
AC distribution and changeover equipment
Mounting structures and roof interfaces
Surge protection devices
Monitoring and data-logging systems
Battery banks where installed
Earthing and lightning protection
Typical maintenance activities
Scheduled PV plant inspection and reporting
String voltage, current and insulation testing
Thermographic inspection of modules and connections
Inverter servicing and fault rectification
Combiner box and protection inspection
Connector and cable-management remediation
Cleaning programme definition and supervision
Generation performance review
Testing & commissioning
String open-circuit voltage and operating current
DC insulation resistance testing
Thermographic survey for hot cells and connections
Earth continuity and protection verification
Inverter functional and protection checks
Performance verification against expected yield
Troubleshooting
Generation below expectation without an obvious cause
Inverter faults, derating and repeated shutdowns
String or module failures and hot spots
DC arcing risk, connector degradation and cable damage
Earth-fault and insulation alarms on the DC side
Preventive & predictive
Preventive
Scheduled inspection and cleaning cycles
Periodic torque and connector checks
Inverter filter, fan and enclosure attention
Annual protection and earthing verification
Predictive
Yield trend analysis against irradiance and expectation
Thermographic trending across inspections
String-level performance comparison over time
Inverter event and alarm history review
Field work
Project & field-work gallery
Select an image for a full-screen view with equipment and work detail.